Classic Built-In units like the BI-36U/S and BI-48SD/S display 95-1-25 when the refrigerator diagnostics check fails. The control checks how the refrigerator side performs and the result did not pass. On the freezer side, the matching…
Classic Built-In units like the BI-36U/S and BI-48SD/S display 95-1-25 when the refrigerator diagnostics check fails. The control checks how the refrigerator side performs and the result did not pass. On the freezer side, the matching 95-2-25 is tied to the coil not cooling while the compressor runs, so we treat this code as a possible cooling-system problem. The fresh-food section may warm gradually.
1. Note 95-1-25. 2. Check the fresh-food temperature with a thermometer. 3. Make sure the toe grille is clear of dust and objects. 4. Reset the unit once from the breaker panel, waiting two minutes before power returns. 5. Book service if the code returns or the temperature rises above 40°F.
It can be. A failed refrigerator diagnostic often points to a cooling problem rather than a setting, so book a visit soon and keep perishables cold in the meantime.
95-1-25 concerns the refrigerator side, while 95-2-25 concerns the freezer side. On these BI models each side has its own cooling, so only one section may be affected.
It depends on what testing finds, from a drive issue to sealed-system work. We test first and give a written price, and our workmanship carries a 30-day warranty.
A technician diagnoses it on site and gives you the price in writing before any work starts.