On Designer units including the DET3050CI and DEC3050R, 10-3-10 means the zone 3 evaporator thermistor reads open, so the control has no coil temperature for that zone. Classic BI models like the BI-36U/S and BI-48SD/S list…
On Designer units including the DET3050CI and DEC3050R, 10-3-10 means the zone 3 evaporator thermistor reads open, so the control has no coil temperature for that zone. Classic BI models like the BI-36U/S and BI-48SD/S list this code as condenser sensor open. On Designer units the evaporator reading guides defrost, so an open sensor can let frost build on the zone 3 coil and reduce cooling over several days. On the Classic BI the control loses its condenser temperature input.
1) Note the full code and your model number. 2) On a Designer unit, look for thick frost on the zone 3 back panel. 3) Do not chip ice or use heat inside the cabinet. 4) Restart at the breaker once. 5) Schedule a visit if the code persists.
The control cannot read the coil temperature, so it may not defrost correctly. Frost can then build on the zone 3 coil and slowly reduce airflow and cooling.
No. On Classic BI units this code is listed as the condenser sensor reading open, which concerns the machine compartment rather than a coil inside the cabinet.
We thaw the coil if necessary, test the sensor and wiring, and replace or repair as needed. Before any of that starts, you see the cost on paper and decide whether to go ahead.
A technician diagnoses it on site and gives you the price in writing before any work starts.