Error code · Refrigerator

Sub-Zero Classic BI and Designer Code 15-4-01: defrost relay will not release

Classic Built-In models like the BI-36UFD/S and Designer units such as the DEC3050R display 15-4-01 when the defrost relay is stuck closed. Designer lists it as the Zone 4 relay. A closed relay keeps power flowing…

High · stop use, call now
Code
15-4-01
Appliance
Refrigerator
Brand
Sub-Zero
Warranty
30-day workmanship

What 15-4-01 means

Classic Built-In models like the BI-36UFD/S and Designer units such as the DEC3050R display 15-4-01 when the defrost relay is stuck closed. Designer lists it as the Zone 4 relay. A closed relay keeps power flowing to the defrost heater when the board wants it off. The coil that should be cooling is being warmed instead, so the freezer or zone loses cold quickly, and you may notice water dripping or unusual warmth inside.

Common causes of 15-4-01

  • Relay contacts welded shut on the control board
  • A board output stuck on
  • A wiring problem that keeps the defrost circuit powered
✓ One safe check you can try

1. Check the freezer temperature right away with a thermometer. 2. If it is rising, move frozen food to another freezer or a cooler with ice. 3. Turn the breaker off if the inside is getting warm, and leave it off until we arrive. 4. Place towels where water drips.

! Why to stop there
  • A heater left on can overheat nearby plastic parts
  • Relay contacts on the board need testing with power applied
  • The board may need replacing, which requires correct programming
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Refrigerator codes

15-4-0115-4-01 questions
Is 15-4-01 urgent?

Yes. The defrost heater stays powered, so the coil warms when it should cool. Food can thaw within hours. Move it out and call us; switching the breaker off stops the heater for now.

Is 15-4-01 worse than 15-4-00?

15-4-00 is the relay stuck open, so defrost never runs and frost builds. 15-4-01 is stuck closed, so defrost never stops. The second one warms the unit much faster.

What will the repair involve?

We confirm the relay state, check the defrost heater and wiring for heat damage, and fix the board side. You get a written price first and a 30-day workmanship warranty.

Book a visit

Still seeing 15-4-01?

A technician diagnoses it on site and gives you the price in writing before any work starts.

☎ Call the desk ▤ Book a Repair