Sub-Zero Designer Code 35-2-00: open circuit on the Zone 2 fan
Sub-Zero Designer refrigeration such as the DET3050CI shows 35-2-00 when Zone 2 reads open in the fan code family, meaning the board finds no complete circuit to the Zone 2 evaporator fan. That fan moves chilled…
- Code
- 35-2-00
- Appliance
- Refrigerator
- Brand
- Sub-Zero
- Warranty
- 30-day workmanship
What 35-2-00 means
Sub-Zero Designer refrigeration such as the DET3050CI shows 35-2-00 when Zone 2 reads open in the fan code family, meaning the board finds no complete circuit to the Zone 2 evaporator fan. That fan moves chilled air across the second compartment. When it stops, cold builds at the coil but does not spread, so Zone 2 starts warming and frost can form behind its panel.
Common causes of 35-2-00
- A Zone 2 fan plug that has come loose
- Fan wiring broken behind the panel
- A Zone 2 evaporator fan motor that has opened
- A missing output from the board
1. Check Zone 2 with a thermometer. 2. Listen for the fan with the door open and the switch held in. 3. Keep vents clear of food. 4. Reset the breaker one time. 5. If temperatures climb, move items to a cooler before we arrive.
- The fan and plug are behind the Zone 2 evaporator cover
- Ice may need melting before the fan can be reached
- Circuit testing is done with power on
Technical reference
- Code
- 35-2-00
- Appliance
- Sub-Zero refrigerator
- Maker documentation
- Sub-Zero owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Sub-Zero.
Other Refrigerator codes
What does Zone 2 mean on my Designer?
Designer models number their compartments, and Zone 2 is the second one, with its own evaporator fan moving air across it. 35-2-00 says that fan's circuit is open.
Will Zone 1 keep working?
Usually yes, since each zone has its own fan. Only Zone 2 loses airflow, so move sensitive items out of Zone 2 if the thermometer there starts climbing.
How do you fix an open fan circuit?
We test the plug, the harness and the motor in that order, then repair or replace the open part. You approve a written price, and labor is covered for 30 days.
Still seeing 35-2-00?
A technician diagnoses it on site and gives you the price in writing before any work starts.