Error code · Refrigerator

Sub-Zero Designer Code 35-2-00: open circuit on the Zone 2 fan

Sub-Zero Designer refrigeration such as the DET3050CI shows 35-2-00 when Zone 2 reads open in the fan code family, meaning the board finds no complete circuit to the Zone 2 evaporator fan. That fan moves chilled…

Medium · inspection needed
Code
35-2-00
Appliance
Refrigerator
Brand
Sub-Zero
Warranty
30-day workmanship

What 35-2-00 means

Sub-Zero Designer refrigeration such as the DET3050CI shows 35-2-00 when Zone 2 reads open in the fan code family, meaning the board finds no complete circuit to the Zone 2 evaporator fan. That fan moves chilled air across the second compartment. When it stops, cold builds at the coil but does not spread, so Zone 2 starts warming and frost can form behind its panel.

Common causes of 35-2-00

  • A Zone 2 fan plug that has come loose
  • Fan wiring broken behind the panel
  • A Zone 2 evaporator fan motor that has opened
  • A missing output from the board
✓ One safe check you can try

1. Check Zone 2 with a thermometer. 2. Listen for the fan with the door open and the switch held in. 3. Keep vents clear of food. 4. Reset the breaker one time. 5. If temperatures climb, move items to a cooler before we arrive.

! Why to stop there
  • The fan and plug are behind the Zone 2 evaporator cover
  • Ice may need melting before the fan can be reached
  • Circuit testing is done with power on
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Refrigerator codes

35-2-0035-2-00 questions
What does Zone 2 mean on my Designer?

Designer models number their compartments, and Zone 2 is the second one, with its own evaporator fan moving air across it. 35-2-00 says that fan's circuit is open.

Will Zone 1 keep working?

Usually yes, since each zone has its own fan. Only Zone 2 loses airflow, so move sensitive items out of Zone 2 if the thermometer there starts climbing.

How do you fix an open fan circuit?

We test the plug, the harness and the motor in that order, then repair or replace the open part. You approve a written price, and labor is covered for 30 days.