Classic Built-In units with electronic control, the BI-36U/S for one, show 90-3-55 when the triac on the control board that switches the condenser fan reads open. A triac is an electronic switch; when it is open,…
Classic Built-In units with electronic control, the BI-36U/S for one, show 90-3-55 when the triac on the control board that switches the condenser fan reads open. A triac is an electronic switch; when it is open, the condenser fan cannot receive power. Without that fan the condenser cannot shed heat, so the compressor runs hot and long, the grille area may feel warm, and both sections slowly lose cold.
1. Note 90-3-55. 2. Check that the toe grille is not blocked by rugs, boxes or lint. 3. Cut power at the panel for roughly two minutes before restoring it. 4. Listen for the condenser fan at the bottom of the unit once the compressor starts. 5. If it stays quiet, keep doors closed and book service.
The condenser fan carries heat away from the cooling system. If its triac is open, the fan never starts, the compressor overheats and cooling falls off in both the fresh-food and freezer sections over a day or two.
Cleaning helps airflow but will not close an open triac on the board. Clear the grille so the unit breathes, then let us test the board output, the fan motor and the wiring between them.
Often, because the triac is soldered onto the board. We confirm it first, rule out the fan and wiring, and give you a written price before any replacement is ordered or installed.
A technician diagnoses it on site and gives you the price in writing before any work starts.