Electronic-control Classic Built-In refrigerators such as the BI-36U/S show 90-5-38 when the control system's FET power output for the 12-volt fans reports an error. This output feeds the low-voltage fans that move air through the unit.…
Electronic-control Classic Built-In refrigerators such as the BI-36U/S show 90-5-38 when the control system's FET power output for the 12-volt fans reports an error. This output feeds the low-voltage fans that move air through the unit. When it drops out, the fans it supplies stop, so air circulation suffers and temperatures can climb unevenly, often with frost or warm spots in one section.
1. Write down 90-5-38. 2. Open a door briefly and listen for interior fans; note which ones are silent. 3. Flip the unit's breaker off for two minutes so the control can restart cleanly. 4. Keep doors closed and put a thermometer in each section. 5. Contact us if the code returns.
The code refers to the board's 12-volt fan supply as a whole. Every fan fed from that supply can go quiet at once, which is why owners often notice more than one fan silent at the same time.
Either. A shorted fan can drag the output down, while a failed output leaves good fans unpowered. We measure each fan on the circuit before deciding which part to replace.
Within a day or two. Without airflow, temperatures drift and frost builds on the coils. We quote the repair in writing and cover our workmanship for 30 days.
A technician diagnoses it on site and gives you the price in writing before any work starts.