Classic Built-In refrigerators with electronic control, the BI-36U/S and BI-36UFD/S among them, record 95-1-01 as a refrigerator diagnostics code. It means the micro-compressor diagnostic pin for the refrigerator compressor is stuck in the on position. The…
Classic Built-In refrigerators with electronic control, the BI-36U/S and BI-36UFD/S among them, record 95-1-01 as a refrigerator diagnostics code. It means the micro-compressor diagnostic pin for the refrigerator compressor is stuck in the on position. The board can no longer trust that signal, so the refrigerator compressor may run far longer than it should, overcooling the fresh-food section or freezing produce, or the control may limit operation to protect the system.
1. Record 95-1-01. 2. Check the fresh-food section with a thermometer for overcooling. 3. Move delicate produce away from the back wall if it is freezing. 4. With the breaker, remove power for two minutes, then return it. 5. Reach out to us if it reappears.
When the refrigerator compressor diagnostic signal is stuck on, the compressor can run longer than needed. That overcools the fresh-food section, which is why lettuce, herbs and fruit near the back may freeze.
Not necessarily. The diagnostic pin reports on the compressor drive. A stuck signal can come from the drive, the wiring or the board, and we test each one before pointing at the compressor.
After testing, we give you a written price. Nothing is replaced without your approval, and our workmanship on the finished repair is covered for 30 days.
A technician diagnoses it on site and gives you the price in writing before any work starts.