On 700 Series 700TF-2 and 700TF-3 units with a variable-speed compressor, the 700TFI among them, code 88 means the serial communication between the control board and the VS compressor controller has failed. One known cause is…
On 700 Series 700TF-2 and 700TF-3 units with a variable-speed compressor, the 700TFI among them, code 88 means the serial communication between the control board and the VS compressor controller has failed. One known cause is lead orientation, so the connection between them should be checked. The code may appear right after a control board replacement. Without that link, the compressor may not run and the unit warms.
1. Note code 88 and when it first appeared. 2. Tell us whether the control board was replaced recently. 3. Give the control a fresh start by keeping the breaker off for two minutes. 4. Keep doors closed and watch temperatures with a thermometer in each section. 5. Call us if code 88 remains.
If the communication leads were plugged in with the wrong orientation, the new board and the VS compressor controller cannot talk. Checking lead orientation is one of the first steps.
No. It concerns the serial link between the board and the controller. The compressor itself may be perfectly fine once communication is restored between the two.
We check lead orientation and the connection, then test the board and controller if needed. You get a written price before any part is replaced.
A technician diagnoses it on site and gives you the price in writing before any work starts.