Classic BI refrigerators like the BI-36U/S and BI-48SD/S report 90-3-38 for a condenser FET power output error. The FET is a switch on the control board that powers the condenser side; this code says that output…
Classic BI refrigerators like the BI-36U/S and BI-48SD/S report 90-3-38 for a condenser FET power output error. The FET is a switch on the control board that powers the condenser side; this code says that output is not working as expected. Without proper condenser airflow, the unit can struggle to shed heat, so temperatures may rise and the compressor may run longer.
1. Clean the grille opening with a soft brush or vacuum so the condenser can breathe. 2. Keep rugs, bags and boxes away from the grille. 3. Restart power at the breaker for one minute. 4. Watch temperatures with a thermometer and call us if the code returns.
A FET is a small electronic switch on the BI control board that powers a load. With 90-3-38, the output feeding the condenser side is not working correctly, so condenser airflow may be affected.
Cleaning helps airflow and is always worth doing, but this code is about the board output itself. If 90-3-38 returns after cleaning and a restart, the board or the wiring needs testing.
We test the condenser output on the board and the wiring to the condenser, then quote in writing before replacing anything. Labor is covered by our 30-day workmanship warranty.
A technician diagnoses it on site and gives you the price in writing before any work starts.