On UC-24 undercounter models with a freezer section, the UC-24F and UC-24CI for example, code 08 tells you the freezer evaporator thermistor read open, shorted for 10 or more seconds, or kept reporting temperatures that did…
On UC-24 undercounter models with a freezer section, the UC-24F and UC-24CI for example, code 08 tells you the freezer evaporator thermistor read open, shorted for 10 or more seconds, or kept reporting temperatures that did not add up. That sensor tracks the freezer cooling coil and guides defrost. Built-in 600/700 refrigerators also print 08, yet their chart is separate from the undercounter one. Owners usually notice frost or ice building inside the freezer, longer run times, or a slow loss of cold.
1. Check the freezer for thick frost on the back or floor. 2. Make sure the freezer door seal is not torn or folded. 3. Do not chip ice from the back wall. 4. Restart the unit at the breaker after one minute off. 5. If ice keeps building or 08 shows again, book service.
The evaporator thermistor tells the control when to defrost the coil. If it reads open or shorted, defrost does not happen on time and ice builds up across the coil and back wall.
Yes. Code 07 is the freezer cabinet sensor that measures air temperature. Code 08 is the freezer evaporator sensor on the cooling coil. They sit in different places and are tested separately.
We clear the ice safely, test the sensor and its wire, and confirm a defrost cycle runs. The price is written before work, and the repair carries our 30-day workmanship warranty.
A technician diagnoses it on site and gives you the price in writing before any work starts.