The zone 3 evaporator thermistor on a Designer Wine (IW) unit like the IW-30CI or IW-30 is reported open when 10 3 10 appears. The sensor on the zone 3 cooling coil shows no circuit, so…
The zone 3 evaporator thermistor on a Designer Wine (IW) unit like the IW-30CI or IW-30 is reported open when 10 3 10 appears. The sensor on the zone 3 cooling coil shows no circuit, so the control cannot read coil temperature or time defrost for zone 3. This is a coil sensor, not a condenser sensor. Frost often builds on the zone 3 coil, airflow weakens, and zone 3 slowly warms.
1. Look for frost through the zone 3 air vents. 2. Never chip ice off the coil. 3. Keep the zone 3 door closed and sealed. 4. Reset the breaker once. 5. Schedule service if frost builds or 10 3 10 returns.
No. It names the zone 3 evaporator thermistor on the cooling coil inside the cabinet. The condenser sensor uses the 10 C codes. Do not mix them up.
Without a coil reading, defrost may not run when needed. Frost builds on the coil and blocks airflow, so the zone warms over days. A thermometer shows the trend.
Melt any ice, test the sensor circuit and replace what failed, after you approve a written price. Work is covered for 30 days. Expect most of a morning.
A technician diagnoses it on site and gives you the price in writing before any work starts.