The IW-30CI combination unit, which pairs wine storage with freezer drawers, can show 40 F 40 for excessive freezer run time. It is the alternate display of 40 4 40 and means the same thing: the…
The IW-30CI combination unit, which pairs wine storage with freezer drawers, can show 40 F 40 for excessive freezer run time. It is the alternate display of 40 4 40 and means the same thing: the freezer drawers needed far more compressor time than normal without reaching temperature. You may find soft frozen food, frost on packages, and a unit that seems to run almost constantly while the wine zones look fine.
1. Close each freezer drawer and check the seal. 2. Remove anything keeping a drawer from closing. 3. Clean the grille. 4. Put a thermometer in the freezer and check it later. 5. If 40 F 40 comes back, move frozen food and call us.
Both refer to the same excessive freezer run time on this model. The display may use either form, and we treat them as one condition.
Usually not directly, but they share the refrigeration system. We check the wine zones too while diagnosing the freezer section. Their temperatures usually stay steady.
Drawer seals and coil frost, then airflow and the sealed system. You get a written price before any work and a 30-day workmanship warranty. Keep frozen food in a cooler meanwhile.
A technician diagnoses it on site and gives you the price in writing before any work starts.