An unstable condenser thermistor triggers 10 C 02 on Designer Wine (IW) models such as the IW-30CI and IW-24. The sensor near the condenser is giving readings that jump around too quickly to be real. The…
An unstable condenser thermistor triggers 10 C 02 on Designer Wine (IW) models such as the IW-30CI and IW-24. The sensor near the condenser is giving readings that jump around too quickly to be real. The control treats the condenser reading as unreliable. You may hear the condenser fan speed up and slow down for no clear reason or notice that the code clears and then returns.
1. Listen for the fan changing speed repeatedly. 2. Keep the grille clean and unblocked. 3. Write down when 10 C 02 appears. 4. Reset at the breaker once. 5. Schedule service if it keeps returning. 6. Keep pets and cords away from the grille.
The control adjusts the condenser fan using the condenser reading. When that reading jumps, the fan follows it, speeding up and slowing down without a real reason.
Yes. The compressor and fan vibrate constantly, and over the years a lead or terminal can loosen. That produces exactly this kind of erratic reading.
We test first and give a written price. Nothing is replaced until you approve, and our work has a 30-day workmanship warranty. Tightening a terminal is often enough.
A technician diagnoses it on site and gives you the price in writing before any work starts.