Code decoder
Sub-Zero error code library
What the code on your display means, whether it is safe to check yourself, and when to stop and call a technician.
- Codes
- 325
- Appliances
- 6
- Updated
- November 2026
Searches by code, appliance and meaning. Dashes and spaces do not matter.
05
Sub-Zero UC-24 Code 05: refrigerator cabinet sensor reading
Undercounter & Drawers · medium
06
Sub-Zero UC-24 Code 06: refrigerator evaporator sensor issue
Undercounter & Drawers · medium
07
Sub-Zero UC-24 Code 07: freezer cabinet thermistor reading
Undercounter & Drawers · medium
08
Sub-Zero UC-24 Code 08: freezer evaporator thermistor
Undercounter & Drawers · medium
22
Sub-Zero UC-24 Code 22: no defrost voltage feedback
Undercounter & Drawers · medium
23
Sub-Zero UC-24 Code 23: defrost overheat without feedback
Undercounter & Drawers · medium
50
Sub-Zero UC-24 Code 50: refrigerator compressor runs too long
Undercounter & Drawers · medium
21
Sub-Zero UC-24 Undercounter Code 21: defrost overheat
Undercounter & Drawers · medium
EE + Service flashing
Sub-Zero UC-24 Undercounter EE with "Service" Flashing: temperature sensor problem
Undercounter & Drawers · medium
Service flashing
Sub-Zero UC-24 Undercounter "Service" Flashing: excessive compressor run
Undercounter & Drawers · high
40-8-01
Sub-Zero Classic Code 40-8-01: ice maker overfilling
Ice Makers · medium
95-D-01
Sub-Zero Designer Ice Maker Code 95-D-01: drain pump float tripped repeatedly
Ice Makers · medium
Ice light flashing (blue)
Sub-Zero UC-15I Ice Maker Blue Ice Light Flashing: automatic shut-off
Ice Makers · medium
45-2-00
Sub-Zero Designer Wine (IW) Code 45-2-00: zone 2 lights not drawing power
Wine Storage · low
45-2-01
Sub-Zero Designer Wine (IW) Code 45-2-01: zone 2 light short circuit
Wine Storage · medium
90-5-80
Sub-Zero Designer Wine (IW) Code 90-5-80: keypad module not talking to the control
Wine Storage · high
90-H-80
Sub-Zero Designer Wine (IW) Code 90-H-80: no communication with the high-voltage micro
Wine Storage · high
90-H-82
Sub-Zero Designer Wine (IW) Code 90-H-82: partial communication with the CCM
Wine Storage · high
90-H-83
Sub-Zero Designer Wine (IW) Code 90-H-83: bad data from the high voltage micro
Wine Storage · high
90-H-84
Sub-Zero Designer Wine (IW) Code 90-H-84: high voltage micro failed to initialize
Wine Storage · high
95-1-00
Sub-Zero Designer Wine (IW) Code 95-1-00: zone 1 door open too long
Wine Storage · low
EC 11
Sub-Zero 400 Series Wine Code EC 11: upper cabinet too cold
Wine Storage · medium
EC 13
Sub-Zero 400 Series Wine Code EC 13: lower cabinet cold alarm
Wine Storage · medium
EC 15
Sub-Zero 400 Series Wine Code EC 15: unit not cooling
Wine Storage · high
Service flashing
Sub-Zero 400 Series Wine "Service" Flashing: compressor ran too long
Wine Storage · high
15-C-00
Sub-Zero Designer Wine (IW) Code 15-C-00: AC condenser fan relay open
Wine Storage · medium
15-C-01
Sub-Zero Designer Wine (IW) Code 15-C-01: condenser fan relay stuck on
Wine Storage · medium
35-1-00
Sub-Zero Designer Wine (IW) Code 35-1-00: zone 1 evaporator fan circuit open
Wine Storage · medium
35-1-33
Sub-Zero Designer Wine (IW) Code 35-1-33: zone 1 fan speed below range
Wine Storage · medium
35-1-34
Sub-Zero Designer Wine (IW) Code 35-1-34: zone 1 fan set too fast
Wine Storage · medium
35-2-00
Sub-Zero Designer Wine (IW) Code 35-2-00: open zone 2 evaporator fan
Wine Storage · medium
35-2-33
Sub-Zero Designer Wine (IW) Code 35-2-33: zone 2 airflow speed too low
Wine Storage · medium
35-2-34
Sub-Zero Designer Wine (IW) Code 35-2-34: zone 2 fan speed over limit
Wine Storage · medium
35-3-33
Sub-Zero Designer Wine (IW) Code 35-3-33: slow zone 3 fan setting
Wine Storage · medium
35-3-34
Sub-Zero Designer Wine (IW) Code 35-3-34: zone 3 fan running above range
Wine Storage · medium
35-C-00
Sub-Zero Designer Wine (IW) Code 35-C-00: DC condenser fan open
Wine Storage · medium
35-C-34
Sub-Zero Designer Wine (IW) Code 35-C-34: condenser fan speed set high
Wine Storage · medium
40-1-00
Sub-Zero Designer Wine (IW) Code 40-1-00: zone 1 stepper motor current out of range
Wine Storage · medium
40-1-40
Sub-Zero Designer Wine (IW) Code 40-1-40: zone 1 cooling runs too long
Wine Storage · high
40-1-87
Sub-Zero Designer Wine (IW) Code 40-1-87: zone 1 stepper not cooling as expected
Wine Storage · high
40-2-00
Sub-Zero Designer Wine (IW) Code 40-2-00: zone 2 stepper current problem
Wine Storage · medium
40-2-87
Sub-Zero Designer Wine (IW) Code 40-2-87: zone 2 not cooling after stepper move
Wine Storage · high
40-3-40
Sub-Zero Designer Wine (IW) Code 40-3-40: zone 3 excessive runtime
Wine Storage · high
40-B-00
Sub-Zero Designer Wine (IW) Code 40-B-00: baffle motor current out of range
Wine Storage · medium
40-B-87
Sub-Zero Designer Wine (IW) Code 40-B-87: baffle not delivering cooling
Wine Storage · high
45-1-00
Sub-Zero Designer Wine (IW) Code 45-1-00: zone 1 light circuit open
Wine Storage · low
45-1-01
Sub-Zero Designer Wine (IW) Code 45-1-01: short in zone 1 lighting
Wine Storage · medium
95-F00
Sub-Zero Designer Wine (IW) Code 95-F00: zone 4 door alert
Wine Storage · low
10-2-01
Sub-Zero Designer Wine (IW) Code 10-2-01: zone 2 cabinet sensor shorted
Wine Storage · medium
10-2-02
Sub-Zero Designer Wine (IW) Code 10-2-02: zone 2 air sensor unstable
Wine Storage · medium
10-2-10
Sub-Zero Designer Wine (IW) Code 10-2-10: zone 2 evaporator sensor open
Wine Storage · medium
10-2-11
Sub-Zero Designer Wine (IW) Code 10-2-11: zone 2 coil thermistor shorted
Wine Storage · medium
10-2-12
Sub-Zero Designer Wine (IW) Code 10-2-12: unstable zone 2 coil reading
Wine Storage · medium
10-3-00
Sub-Zero Designer Wine (IW) Code 10-3-00: zone 3 cabinet thermistor open
Wine Storage · medium
10-3-01
Sub-Zero Designer Wine (IW) Code 10-3-01: shorted zone 3 air sensor
Wine Storage · medium
10-3-02
Sub-Zero Designer Wine (IW) Code 10-3-02: zone 3 sensor reading unstable
Wine Storage · medium
10-3-10
Sub-Zero Designer Wine (IW) Code 10-3-10: zone 3 coil sensor open
Wine Storage · medium
10 1 00
Sub-Zero Designer Wine (IW) Code 10 1 00: no signal from zone 1 air sensor
Wine Storage · medium
10 1 01
Sub-Zero Designer Wine (IW) Code 10 1 01: zone 1 cabinet thermistor short
Wine Storage · medium
10 1 02
Sub-Zero Designer Wine (IW) Code 10 1 02: zone 1 air reading erratic
Wine Storage · medium
10 1 10
Sub-Zero Designer Wine (IW) Code 10 1 10: zone 1 evaporator thermistor open
Wine Storage · medium
10 1 11
Sub-Zero Designer Wine (IW) Code 10 1 11: zone 1 coil sensor shorted
Wine Storage · medium
10 1 12
Sub-Zero Designer Wine (IW) Code 10 1 12: zone 1 coil reading unstable
Wine Storage · medium
10 2 00
Sub-Zero Designer Wine (IW) Code 10 2 00: zone 2 air thermistor open
Wine Storage · medium
10 C 00
Sub-Zero Designer Wine (IW) Code 10 C 00: condenser thermistor open
Wine Storage · medium
10 C 01
Sub-Zero Designer Wine (IW) Code 10 C 01: condenser sensor shorted
Wine Storage · medium
10 C 02
Sub-Zero Designer Wine (IW) Code 10 C 02: erratic condenser sensor
Wine Storage · medium
35 C 33
Sub-Zero Designer Wine (IW) Code 35 C 33: condenser fan speed too low
Wine Storage · medium
95 2 00
Sub-Zero Designer Wine (IW) Code 95 2 00: zone 2 door open alert
Wine Storage · low
40 F 40
Sub-Zero IW-30CI Code 40 F 40: freezer drawer run time too long
Wine Storage · medium
10-3-11
Sub-Zero Designer Wine (IW) Code 10-3-11: zone 3 evaporator sensor shorted
Wine Storage · medium
10-3-12
Sub-Zero Designer Wine (IW) Code 10-3-12: unstable zone 3 coil thermistor
Wine Storage · medium
10-7-00
Sub-Zero Designer Wine (IW) Code 10-7-00: open room-temperature sensor on the board
Wine Storage · medium
15-1-00
Sub-Zero Designer Wine (IW) Code 15-1-00: zone 1 compressor relay will not close
Wine Storage · high
15-1-01
Sub-Zero Designer Wine (IW) Code 15-1-01: zone 1 compressor relay welded shut
Wine Storage · high
15-2-00
Sub-Zero Designer Wine (IW) Code 15-2-00: no power path to the zone 2 compressor
Wine Storage · high
15-2-01
Sub-Zero Designer Wine (IW) Code 15-2-01: zone 2 compressor will not shut off
Wine Storage · high
15-3-00
Sub-Zero Designer Wine (IW) Code 15-3-00: zone 3 compressor relay stuck open
Wine Storage · high
15-3-01
Sub-Zero Designer Wine (IW) Code 15-3-01: zone 3 cooling stuck on
Wine Storage · high
23
Sub-Zero 600, 700 and 648PRO Code 23: Defrost overheat with no feedback
Refrigerator · medium
50
Sub-Zero 600 and 700 Series Code 50: Refrigerator compressor running too long
Refrigerator · high
41
Sub-Zero 648PRO Code 41: Zone compressor or wiring problem
Refrigerator · high
81
Sub-Zero 700-2 Code 81: Variable-Speed compressor fails to start
Refrigerator · high
82
Sub-Zero 700-2 Code 82: VS compressor controller needs replacement
Refrigerator · high
88
Sub-Zero 700TF Code 88: Board and compressor controller not talking
Refrigerator · high
80
Sub-Zero 700TF Code 80: No inverter feedback after a board change
Refrigerator · high
dd
Sub-Zero 600 and 700 Series Display dd: Diagnostics switched off
Refrigerator · low
de
Sub-Zero 600 and 700 Series Display de: Diagnostics enabled
Refrigerator · low
60-202
Sub-Zero Classic Code 60-202: freezer compressor drive unstable
Freezers · high
60-238
Sub-Zero Classic Code 60-238: freezer compressor power output problem
Freezers · high
35 3 00
Sub-Zero Designer Wine (IW) Code 35 3 00: zone 3 fan circuit open
Wine Storage · medium
40 1 09
Sub-Zero Designer Wine (IW) Code 40 1 09: zone 1 temperature out of range
Wine Storage · medium
40 2 09
Sub-Zero Designer Wine (IW) Code 40 2 09: zone 2 cooling alarm
Wine Storage · medium
40 2 40
Sub-Zero Designer Wine (IW) Code 40 2 40: zone 2 runs too long
Wine Storage · medium
40 4 40
Sub-Zero IW-30CI Code 40 4 40: freezer drawers run too long
Wine Storage · medium
EC 06
Sub-Zero BW-30 Wine Code EC 06: upper coil sensor reading
Wine Storage · medium
EC 10 / EC 12
Sub-Zero 400 Series Wine Code EC 10 / EC 12: warm cabinet alarms
Wine Storage · medium
EC 15
Sub-Zero UW-24 Wine Code EC 15: sealed system problem
Wine Storage · high
2
Sub-Zero UW-24 Wine Code 2: factory programming error
Wine Storage · high
3
Sub-Zero UW-24 Wine Code 3: control setup data mismatch
Wine Storage · high
EC-05
Sub-Zero BW-30/UW-24 Wine Code EC-05: upper cabinet sensor
Wine Storage · medium
EC-07
Sub-Zero BW-30/UW-24 Wine Code EC-07: lower cabinet thermistor
Wine Storage · medium
EC-08
Sub-Zero BW-30/UW-24 Wine Code EC-08: lower coil sensor reading
Wine Storage · medium
EC-10
Sub-Zero BW-30/UW-24 Wine Code EC-10: upper zone too warm
Wine Storage · medium
EC-11
Sub-Zero BW-30/UW-24 Wine Code EC-11: upper zone too cold
Wine Storage · medium
EC-12
Sub-Zero BW-30/UW-24 Wine Code EC-12: lower cabinet warm alarm
Wine Storage · medium
EC-13
Sub-Zero BW-30/UW-24 Wine Code EC-13: lower section too cold
Wine Storage · medium
40-309
Sub-Zero Designer Wine (IW) Code 40-309: zone 3 off temperature
Wine Storage · medium
95-300
Sub-Zero Designer Wine (IW) Code 95-300: zone 3 door left open
Wine Storage · low
90-5-38
Sub-Zero Classic BI Code 90-5-38: 12-Volt fan supply lost
Refrigerator · high
90-5-44
Sub-Zero Classic BI Code 90-5-44: Glass door heater output error
Refrigerator · medium
90-5-85
Sub-Zero Classic BI Code 90-5-85: User display not working
Refrigerator · medium
90-5-95
Sub-Zero Classic BI Code 90-5-95: Keypad self-check failed
Refrigerator · medium
90-5-96
Sub-Zero Classic BI Code 90-5-96: Keypad signal too weak
Refrigerator · medium
90-5-97
Sub-Zero Classic BI Code 90-5-97: Control panel processor problem
Refrigerator · medium
90-5-99
Sub-Zero Classic BI Code 90-5-99: Keypad not responding
Refrigerator · medium
90-9-80
Sub-Zero Classic BI Code 90-9-80: Door dispenser not communicating
Refrigerator · medium
90-A-38
Sub-Zero Classic BI Code 90-A-38: Air filter fan output error
Refrigerator · high
90-B-80
Sub-Zero Classic BI Code 90-B-80: Baffle stepper not communicating
Refrigerator · medium
90-F-38
Sub-Zero Classic BI Code 90-F-38: Freezer evaporator fan output error
Refrigerator · high
90-L-38
Sub-Zero Classic BI Code 90-L-38: Interior lighting output error
Refrigerator · medium
90-R-38
Sub-Zero Classic BI Code 90-R-38: Refrigerator evaporator fan output error
Refrigerator · high
95-1-01
Sub-Zero Classic BI Code 95-1-01: Refrigerator compressor signal stuck on
Refrigerator · high
95-2-00
Sub-Zero BI and Designer Code 95-2-00: Freezer signal off or zone 2 door open
Refrigerator · high
95-2-01
Sub-Zero Classic BI Code 95-2-01: Freezer compressor signal stuck on
Refrigerator · high
95-2-25
Sub-Zero Classic BI Code 95-2-25: Freezer coil not getting cold
Refrigerator · high
95-3-00
Sub-Zero Designer and PRO Code 95-3-00: Zone 3 door left open
Refrigerator · low
95-X-00
Sub-Zero Designer Code 95-X-00: A zone door stayed open too long
Refrigerator · low
98-0-98
Sub-Zero Classic BI Code 98-0-98: Low voltage detected
Refrigerator · high
90-H-83
Sub-Zero Designer and BI Code 90-H-83: High-Voltage board lost contact
Refrigerator · high
90-H-84
Sub-Zero Designer and BI Code 90-H-84: High-Voltage micro restarted
Refrigerator · high
95-1-00
Sub-Zero Designer and BI Code 95-1-00: Zone 1 door or refrigerator diagnostic
Refrigerator · medium
95-1-25
Sub-Zero Classic BI Code 95-1-25: Refrigerator diagnostic check failed
Refrigerator · high
95-F-00
Sub-Zero Designer Code 95-F-00: Zone 4 door left open
Refrigerator · low
05
Sub-Zero 600 and 700 Series Code 05: Refrigerator cabinet sensor reading lost
Refrigerator · medium
06
Sub-Zero 600 and 700 Series Code 06: Refrigerator evaporator sensor error
Refrigerator · medium
07
Sub-Zero 600 and 700 Series Code 07: Freezer cabinet thermistor problem
Refrigerator · medium
08
Sub-Zero 600 and 700 Series Code 08: Freezer coil thermistor reading bad
Refrigerator · medium
22
Sub-Zero 600, 700 and 648PRO Code 22: No defrost voltage feedback
Refrigerator · medium
45-2-01
Sub-Zero Designer/BI Code 45-2-01: Zone 2 lighting short
Refrigerator · low
50-U-80
Sub-Zero Classic BI Code 50-U-80: Water system not communicating
Refrigerator · medium
60-2-02
Sub-Zero Classic BI Code 60-2-02: Freezer system unstable
Refrigerator · high
90-3-38
Sub-Zero Classic BI Code 90-3-38: Condenser output on the board
Refrigerator · high
90-5-39
Sub-Zero Classic BI Code 90-5-39: Control board DC output problem
Refrigerator · high
90-5-80
Sub-Zero Designer/BI Code 90-5-80: Control system lost communication
Refrigerator · high
90-A-56
Sub-Zero Classic BI Code 90-A-56: Air filter triac shorted on board
Refrigerator · high
90-H-80
Sub-Zero Designer/BI Code 90-H-80: High voltage board not responding
Refrigerator · high
90-H-82
Sub-Zero Designer/BI Code 90-H-82: Partial link to high voltage board
Refrigerator · high
60-1-38
Sub-Zero Classic BI Code 60-1-38: Fresh-food compressor drive not talking
Refrigerator · high
60-1-60
Sub-Zero Classic BI Code 60-1-60: No refrigerator compressor load seen
Refrigerator · high
60-2-38
Sub-Zero Classic BI Code 60-2-38: Freezer compressor communication lost
Refrigerator · high
60-2-60
Sub-Zero Classic BI Code 60-2-60: Freezer compressor draws no current
Refrigerator · high
90-0-70
Sub-Zero Classic BI Code 90-0-70: Control could not save to memory
Refrigerator · high
90-0-71
Sub-Zero Classic BI Code 90-0-71: Flash memory was re-initialized
Refrigerator · high
90-0-72
Sub-Zero Classic BI Code 90-0-72: Bad flash memory detected
Refrigerator · high
90-0-73
Sub-Zero Classic BI Code 90-0-73: Board cannot find its flash memory
Refrigerator · high
90-0-74
Sub-Zero Classic BI Code 90-0-74: Stored settings failed their check
Refrigerator · high
90-0-75
Sub-Zero Classic BI Code 90-0-75: Model data checksum mismatch
Refrigerator · high
90-0-81
Sub-Zero Classic BI Code 90-0-81: Board communication timed out
Refrigerator · high
90-0-90
Sub-Zero Classic BI Code 90-0-90: Garbled data between boards
Refrigerator · high
90-0-92
Sub-Zero Classic BI Code 90-0-92: Too many data collisions
Refrigerator · high
90-0-93
Sub-Zero Classic BI Code 90-0-93: Control overwhelmed by data
Refrigerator · high
90-3-55
Sub-Zero Classic BI Code 90-3-55: Condenser fan switch open
Refrigerator · high
90-3-56
Sub-Zero Classic BI Code 90-3-56: Condenser fan switch shorted
Refrigerator · high
90-5-01
Sub-Zero Classic BI Code 90-5-01: Keypad key reads shorted
Refrigerator · medium
60-1-02
Sub-Zero Classic BI Code 60-1-02: Refrigerator compressor link unstable
Refrigerator · high
40-2-40
Sub-Zero Code 40-2-40: Zone 2 cooling ran past its time limit
Refrigerator · high
40-2-87
Sub-Zero Designer Code 40-2-87: No flow reported in Zone 2
Refrigerator · medium
40-3-40
Sub-Zero CL Code 40-3-40: Zone 3 compressor running too long
Refrigerator · high
40-8-01
Sub-Zero CL Code 40-8-01: Ice maker overfilling
Refrigerator · medium
40-B-00
Sub-Zero Designer Code 40-B-00: Air baffle circuit open
Refrigerator · medium
40-B-87
Sub-Zero Designer Code 40-B-87: Baffle shows no air flow
Refrigerator · medium
45-1-00
Sub-Zero Designer/BI Code 45-1-00: Zone 1 light circuit open
Refrigerator · low
45-1-01
Sub-Zero Code 45-1-01: Refrigerator light circuit shorted
Refrigerator · low
45-2-00
Sub-Zero Designer/BI Code 45-2-00: Freezer lights not lighting
Refrigerator · low
44-9-43
Sub-Zero Classic BI Code 44-9-43: 4-watt glasswell heater not found
Refrigerator · medium
45-A-45
Sub-Zero Classic BI Code 45-A-45: Air filter indicator light out
Refrigerator · low
45-L-00
Sub-Zero Classic BI Code 45-L-00: Accent lights open circuit
Refrigerator · low
45-L-01
Sub-Zero Classic BI Code 45-L-01: Accent lighting short
Refrigerator · low
50-U-86
Sub-Zero Classic BI Code 50-U-86: Water flow too slow
Refrigerator · medium
50-U-87
Sub-Zero Classic BI Code 50-U-87: Flow meter detects no water
Refrigerator · medium
20-2-07
Sub-Zero Classic BI Code 20-2-07: Defrost heater bad ohms reading
Refrigerator · medium
20-2-50
Sub-Zero BI/Designer Code 20-2-50: Defrost heater open
Refrigerator · medium
20-4-50
Sub-Zero CL/Designer Code 20-4-50: Defrost heater failed open
Refrigerator · medium
30-8-00
Sub-Zero Classic BI Code 30-8-00: Ice accessories open circuit
Refrigerator · low
30-8-05
Sub-Zero BI/Designer Code 30-8-05: Ice maker fill signal missing
Refrigerator · low
30-8-10
Sub-Zero Classic BI Code 30-8-10: Ice maker open circuit
Refrigerator · low
30-8-30
Sub-Zero Classic BI Code 30-8-30: Ice maker valve on too long
Refrigerator · medium
30-9-01
Sub-Zero Classic BI Code 30-9-01: Bulk ice switch stuck closed
Refrigerator · low
30-9-10
Sub-Zero Classic BI Code 30-9-10: Dispenser auger circuit open
Refrigerator · low
30-9-80
Sub-Zero Classic BI Code 30-9-80: Dispenser not communicating
Refrigerator · medium
30-9-86
Sub-Zero Classic BI Code 30-9-86: Dispenser chute motor timed out
Refrigerator · low
30-U-00
Sub-Zero Classic BI Code 30-U-00: Water valve open circuit
Refrigerator · medium
30-U-10
Sub-Zero Classic BI Code 30-U-10: Dispenser water valve open
Refrigerator · medium
30-U-20
Sub-Zero Classic BI Code 30-U-20: Water check valve open circuit
Refrigerator · medium
35-A-00
Sub-Zero Designer Code 35-A-00: Air filter fan open
Refrigerator · medium
35-A-36
Sub-Zero Classic BI Code 35-A-36: Air filter fan current low
Refrigerator · medium
35-A-37
Sub-Zero Classic BI Code 35-A-37: Air filter fan shorted
Refrigerator · medium
35-C-33
Sub-Zero Designer Code 35-C-33: Condenser fan speed set too low
Refrigerator · medium
35-F-33
Sub-Zero Classic BI Code 35-F-33: Freezer fan speed too low
Refrigerator · medium
35-F-34
Sub-Zero Classic BI Code 35-F-34: Freezer fan shorted
Refrigerator · medium
35-R-33
Sub-Zero Classic BI Code 35-R-33: Refrigerator fan running slow
Refrigerator · medium
35-R-34
Sub-Zero Classic BI Code 35-R-34: Refrigerator fan shorted
Refrigerator · medium
40-1-38
Sub-Zero Classic BI Code 40-1-38: Refrigerator stepper valve link
Refrigerator · high
40-2-38
Sub-Zero Classic BI Code 40-2-38: Freezer FET output error
Refrigerator · high
40-8-40
Sub-Zero Classic BI Code 40-8-40: Ice maker fill time exceeded
Refrigerator · medium
40-9-40
Sub-Zero Code 40-9-40: Dispenser ran past its time limit
Refrigerator · medium
40-B-38
Sub-Zero Classic BI Code 40-B-38: Baffle stepper not communicating
Refrigerator · high
44-0-00
Sub-Zero Classic BI Code 44-0-00: Glass door heater connector open
Refrigerator · medium
44-0-01
Sub-Zero Classic BI Code 44-0-01: Glass door heater short
Refrigerator · medium
44-9-42
Sub-Zero Classic BI Code 44-9-42: 1-watt glasswell heater missing
Refrigerator · medium
15-8-01
Sub-Zero Classic BI Code 15-8-01: ice maker relay stuck closed
Refrigerator · medium
15-8-10
Sub-Zero Classic BI Code 15-8-10: ice accessories relay open
Refrigerator · medium
15-8-11
Sub-Zero Classic BI Code 15-8-11: second ice relay stuck on
Refrigerator · medium
15-9-00
Sub-Zero Classic BI Code 15-9-00: dispenser auger relay open
Refrigerator · medium
15-9-01
Sub-Zero Classic BI Code 15-9-01: auger relay stuck closed
Refrigerator · medium
15-9-65
Sub-Zero Classic BI Code 15-9-65: valve selector stuck at dispenser
Refrigerator · medium
15-9-66
Sub-Zero Classic BI Code 15-9-66: water selector held at ice maker
Refrigerator · medium
15-L-00
Sub-Zero Classic BI Code 15-L-00: main lights relay open
Refrigerator · low
15-L-01
Sub-Zero Classic BI Code 15-L-01: lighting relay stays closed
Refrigerator · low
15-U-00
Sub-Zero Classic BI and Designer Code 15-U-00: water valve gets no current
Refrigerator · medium
15-U-01
Sub-Zero Classic BI and Designer Code 15-U-01: water relay shorted or stuck closed
Refrigerator · medium
15-U-10
Sub-Zero Classic BI Code 15-U-10: water check valve relay open
Refrigerator · medium
15-U-11
Sub-Zero Classic BI Code 15-U-11: check valve relay stuck closed
Refrigerator · medium
20-2-00
Sub-Zero Classic BI and Designer Code 20-2-00: defrost heater circuit open
Refrigerator · medium
15-C-01
Sub-Zero Designer Code 15-C-01: condenser relay stuck closed
Refrigerator · medium
15-L-55
Sub-Zero Classic BI Code 15-L-55: lighting triac reads open
Refrigerator · low
15-L-56
Sub-Zero Classic BI Code 15-L-56: lights triac stuck on
Refrigerator · low
35-1-00
Sub-Zero Designer Code 35-1-00: Zone 1 fan circuit open
Refrigerator · medium
35-1-33
Sub-Zero Designer, CL and PRO Code 35-1-33: Zone 1 evaporator fan too slow
Refrigerator · medium
35-1-34
Sub-Zero Designer Code 35-1-34: Zone 1 fan speed above setting
Refrigerator · medium
35-2-00
Sub-Zero Designer Code 35-2-00: open circuit on the Zone 2 fan
Refrigerator · medium
35-2-33
Sub-Zero Designer, CL and PRO Code 35-2-33: slow evaporator fan in Zone 2
Refrigerator · medium
35-2-34
Sub-Zero Designer Code 35-2-34: Zone 2 fan running faster than set
Refrigerator · medium
35-3-00
Sub-Zero Designer and Classic BI Code 35-3-00: open fan circuit, Zone 3 or condenser
Refrigerator · medium
35-3-33
Sub-Zero Designer Code 35-3-33: Zone 3 fan speed below setting
Refrigerator · medium
35-3-34
Sub-Zero Designer Code 35-3-34: Zone 3 fan over speed
Refrigerator · medium
35-C-00
Sub-Zero Designer Code 35-C-00: condenser fan circuit open
Refrigerator · high
35-C-34
Sub-Zero Designer Code 35-C-34: condenser fan speed too high
Refrigerator · medium
20-2-01
Sub-Zero BI/Designer Code 20-2-01: Defrost bi-metal stuck closed
Refrigerator · medium
20-2-05
Sub-Zero BI/Designer Code 20-2-05: Bi-metal miswire, normal temps
Refrigerator · medium
20-2-06
Sub-Zero BI/Designer Code 20-2-06: Bi-metal miswire with overheat
Refrigerator · medium
15-C-00
Sub-Zero Designer Code 15-C-00: Condenser circuit relay open
Refrigerator · medium
H2-LO
Sub-Zero Classic BI Code H2-LO: water dispenser in safety lock
Refrigerator · low
10-0-00
Sub-Zero Designer Code 10-0-00: unprogrammed board or open DEFL thermistor
Refrigerator · medium
10-0-01
Sub-Zero Designer Code 10-0-01: shorted thermistor on a DEFL setup
Refrigerator · medium
10-0-02
Sub-Zero Designer Code 10-0-02: thermistor signal is unstable
Refrigerator · medium
10-1-00
Sub-Zero Classic BI and Designer Code 10-1-00: open sensor in the refrigerator or Zone 1
Refrigerator · medium
10-1-01
Sub-Zero Classic BI and Designer Code 10-1-01: cabinet sensor has shorted
Refrigerator · medium
10-1-02
Sub-Zero Classic BI and Designer Code 10-1-02: unstable reading from the Zone 1 cabinet sensor
Refrigerator · medium
10-1-10
Sub-Zero Designer Code 10-1-10: Zone 1 coil sensor circuit open
Refrigerator · medium
10-1-11
Sub-Zero CL, Designer and Legacy Designer Code 10-1-11: short in the Zone 1 evaporator thermistor
Refrigerator · medium
10-1-12
Sub-Zero Designer Code 10-1-12: jumpy Zone 1 evaporator sensor
Refrigerator · medium
10-2-00
Sub-Zero Classic BI and Designer Code 10-2-00: freezer or Zone 2 thermistor reads open
Refrigerator · medium
10-7-01
Sub-Zero Classic BI Code 10-7-01: room air sensor shorted
Refrigerator · medium
10-7-02
Sub-Zero Classic BI Code 10-7-02: ambient thermistor gives an unstable value
Refrigerator · medium
10-C-00
Sub-Zero Designer Code 10-C-00: condenser sensor circuit is open
Refrigerator · medium
10-C-01
Sub-Zero Designer Code 10-C-01: short at the condenser thermistor
Refrigerator · medium
10-C-02
Sub-Zero Designer Code 10-C-02: condenser reading jumps around
Refrigerator · medium
10-F-00
Sub-Zero Classic BI Code 10-F-00: freezer coil thermistor open
Refrigerator · medium
10-F-01
Sub-Zero Classic BI Code 10-F-01: shorted sensor on the freezer evaporator
Refrigerator · medium
10-F-02
Sub-Zero Classic BI Code 10-F-02: freezer evaporator signal unstable
Refrigerator · medium
10-R-00
Sub-Zero Classic BI Code 10-R-00: open thermistor on the fresh-food coil
Refrigerator · medium
10-R-02
Sub-Zero Classic BI Code 10-R-02: fresh-food coil sensor reads unstable
Refrigerator · medium
10-R-09
Sub-Zero Classic BI Code 10-R-09: refrigerator coil reads too warm
Refrigerator · medium
15-4-00
Sub-Zero BI, CL and Designer Code 15-4-00: defrost relay stuck open
Refrigerator · medium
15-4-01
Sub-Zero Classic BI and Designer Code 15-4-01: defrost relay will not release
Refrigerator · high
15-8-00
Sub-Zero Classic BI Code 15-8-00: ice maker relay stays open
Refrigerator · medium
90
Sub-Zero 648PRO Code 90: Main control board needs replacing
Refrigerator · high
91
Sub-Zero 648PRO Code 91: Lights staying on
Refrigerator · low
92
Sub-Zero 648PRO Code 92: Keypad wiring problem
Refrigerator · medium
93
Sub-Zero 648PRO Code 93: Keypad replacement needed
Refrigerator · medium
94
Sub-Zero 648PRO Code 94: User display or its wiring
Refrigerator · medium
96
Sub-Zero 648PRO Code 96: Datalogger not working
Refrigerator · low
97
Sub-Zero 648PRO Code 97: Communication cables or connectors
Refrigerator · medium
98
Sub-Zero 648PRO Code 98: Brownout on the supply line
Refrigerator · high
L0-C
Sub-Zero Classic BI Code L0 C: Controls locked out
Refrigerator · low
EC-30
Sub-Zero 600/700 Code EC 30: Ice maker valve overrun
Refrigerator · medium
EC-40
Sub-Zero 600/700 Code EC 40: Freezer compressor overrun
Refrigerator · medium
10-2-01
Sub-Zero Designer Code 10-2-01: Zone 2 sensor shorted
Refrigerator · medium
10-2-02
Sub-Zero Designer Code 10-2-02: Unstable zone 2 reading
Refrigerator · medium
10-2-10
Sub-Zero Designer Code 10-2-10: Zone 2 evaporator thermistor open
Refrigerator · medium
10-2-11
Sub-Zero Designer Code 10-2-11: Zone 2 coil sensor shorted
Refrigerator · medium
10-2-12
Sub-Zero Designer Code 10-2-12: Zone 2 coil reading unstable
Refrigerator · medium
10-3-00
Sub-Zero Designer Code 10-3-00: Zone 3 sensor open
Refrigerator · medium
10-3-01
Sub-Zero Designer Code 10-3-01: Zone 3 thermistor shorted
Refrigerator · medium
10-3-02
Sub-Zero Designer Code 10-3-02: Erratic zone 3 temperature signal
Refrigerator · medium
10-3-10
Sub-Zero Designer Code 10-3-10: Zone 3 coil sensor open
Refrigerator · medium
10-3-11
Sub-Zero Designer Code 10-3-11: Zone 3 evaporator sensor short
Refrigerator · medium
10-3-12
Sub-Zero Designer Code 10-3-12: Zone 3 coil reading jumps
Refrigerator · medium
10-7-00
Sub-Zero Designer Code 10-7-00: Ambient sensor open
Refrigerator · medium
15-1-00
Sub-Zero Designer Code 15-1-00: Zone 1 cooling relay stuck open
Refrigerator · medium
15-2-00
Sub-Zero Designer Code 15-2-00: Zone 2 relay not switching on
Refrigerator · medium
15-2-01
Sub-Zero Designer Code 15-2-01: Zone 2 relay stuck closed
Refrigerator · medium
15-3-00
Sub-Zero Designer Code 15-3-00: Zone 3 cooling relay open
Refrigerator · medium
15-3-01
Sub-Zero Designer Code 15-3-01: Zone 3 relay closed when it should open
Refrigerator · medium
600-40
Sub-Zero 600 Series Code 40: Freezer compressor overrun
Refrigerator · medium
700-40
Sub-Zero 700 Series Code 40: Freezer running excessively
Refrigerator · medium
EC50
Sub-Zero 600/700 Code EC50: Refrigerator compressor overrun
Refrigerator · medium
01
Sub-Zero 648PRO Code 01: Cabinet thermistor problem
Refrigerator · medium
02
Sub-Zero 648PRO Code 02: Evaporator sensor issue in one zone
Refrigerator · medium
03
Sub-Zero 648PRO Code 03: Condenser thermistor reading lost
Refrigerator · medium
04
Sub-Zero 648PRO Code 04: Ambient sensor not reading
Refrigerator · medium
20
Sub-Zero Code 20: Defrost did not heat correctly
Refrigerator · medium
21
Sub-Zero Code 21: Defrost overheat reported
Refrigerator · medium
24
Sub-Zero Code 24: Defrost heater underheat
Refrigerator · medium
30
Sub-Zero Code 30: Ice maker water valve overuse
Refrigerator · medium
35
Sub-Zero 648PRO Code 35: Zone fan speed wrong
Refrigerator · medium
40
Sub-Zero Code 40: Compressor ran too long
Refrigerator · medium
42
Sub-Zero 648PRO Code 42: Condenser fan circuit check
Refrigerator · medium
43
Sub-Zero 648PRO Code 43: Left refrigerant valve circuit
Refrigerator · high
44
Sub-Zero 648PRO Code 44: Glass door heater circuit
Refrigerator · medium
45
Sub-Zero 648PRO Code 45: Overhead lights
Refrigerator · low
46
Sub-Zero 648PRO Code 46: Ice accessory wiring open
Refrigerator · medium
47
Sub-Zero 648PRO Code 47: Accent lighting short
Refrigerator · low
80
Sub-Zero 648PRO Code 80: Compressor controller has no power
Refrigerator · high
83
Sub-Zero 648PRO Code 83: Variable-Speed compressor problem
Refrigerator · high
84
Sub-Zero 648PRO Code 84: Variable-Speed compressor wiring
Refrigerator · high
85
Sub-Zero 648PRO Code 85: VS compressor control too hot
Refrigerator · high
86
Sub-Zero 648PRO Code 86: Controller not talking to the board
Refrigerator · high
87
Sub-Zero 648PRO Code 87: Open defrost heater or broken wire
Refrigerator · medium
89
Sub-Zero 648PRO Code 89: Ice maker water valve circuit
Refrigerator · medium
10/R/01
Sub-Zero Classic BI Code 10/R/01: Refrigerator evaporator sensor shorted
Refrigerator · medium
15/1/01
Sub-Zero Classic BI Code 15/1/01: Compressor relay stuck closed
Refrigerator · medium
40/1/40
Sub-Zero Code 40/1/40: Zone 1 running too long
Refrigerator · medium
Book a visit